HPLC Column, Axis C18, 5um, 4.6mm ID x 250mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
The 59021‑25P Cogent Axis C18™ HPLC Column is a proven, legacy reversed‑phase column, trusted for years by laboratories requiring reliable, reproducible performance in USP L1 methods.
Constructed with a fully double end‑capped C18 bonded phase on high‑purity silica, this column minimizes secondary interactions and ensures stable retention, excellent peak shape, and method reproducibility.
✅ Widely used as a standard reference column for USP L1 applications
250 mm Length – Maximum Resolution & Separation Power
Provides the highest resolving power in the Axis C18 analytical range
Maximizes peak capacity for highly complex mixtures
Ideal for:
closely eluting analytes
impurity profiling and trace analysis
Increases retention and separation efficiency
✅ Selected when maximum separation and analytical precision are required
4.6 mm ID – Standard Analytical Platform
Compatible with standard HPLC systems
Ideal for:
routine QC analysis
method validation and regulatory testing
Typical Flow Rate Range
~0.8–1.5 mL/min
✅ Provides robust, reproducible, and transferable results
5 µm Particle – Reliable Performance & Low Backpressure
Provides:
Consistent efficiency for analytical methods
Lower backpressure vs smaller particle sizes
Long operational lifetime
✅ Ideal for:
Routine laboratory workflows
Method transfer across multiple systems
100 Å Pore Size – Standard Small Molecule Analysis
Optimized for:
small molecules
traditional reversed‑phase separations
Provides:
Consistent interaction with hydrophobic and neutral compounds
Predictable chromatographic behavior
✅ Ensures reliable performance in USP L1 methods
Why Choose Axis C18™ Columns
Proven Legacy Performance
Widely used in analytical labs for many years
Known for consistency and reliability
USP L1 Compatibility
Ideal for USP L1 methods requiring standard C18 phases
Supports method validation and transfer
Predictable Selectivity
Traditional reversed‑phase retention behavior
Reliable across standard analytical applications
✅ Preferred for routine and regulated laboratory workflows
Application Performance Advantages
Suitable for:
Hydrophobic compounds
Neutral analytes
Long‑chain fatty acids
Provides:
Longer retention than C8 columns
Improved separation for non‑polar analytes
✅ Ideal for general‑purpose reversed‑phase chromatography
System & Sample Considerations
Compatible with standard HPLC systems
Suitable for routine and high‑throughput workflows
Recommended sample preparation:
👉 Use 0.2 µm syringe filters for proper sample preparation before injection
✅ Helps:
Prevent column fouling
Maintain consistent analytical performance
Typical Applications
USP L1 analytical methods
Pharmaceutical QC and validation
Routine HPLC analysis
Complex mixture separations
Impurity profiling
Long‑chain fatty acid analysis
Important Usage Notes
Designed for standard analytical HPLC systems (4.6 mm ID)
Ideal for maximum resolution analytical workflows
Suitable for USP L1 method development and validation
Monitor system pressure based on instrument specifications